  1. Sterilization Volume: 1.8L, 5.2L, 6L
  2. The whole sterilization process is less than 10 minutes
  3. Maximum Operating Temperature: 138° C
  4. Maximum Operating Pressure: 242 kPa

Share the product

Description

Autoclave/ Sterilizer

STC-2000:

1. The sterilization effect is reliable, rapid. The whole process of non-wrapped sterilization time is 6 minutes, suitable for stomatology, ophthalmology and other departments of small instruments.
2. Equipment size: 57 CM*41.5CM*17CM; sterilization chamber size: 28CM*18CM* 3.8cm; Sterilization box size (outside) : 39 CM *19.6 CM *4CM.
3. It is easy to operate, the system operation is displayed on the screen; Sterilization procedures can be safely interrupted at any time.
4. With self-detection system, if a problem occurs in the process of operation, the system will automatically stop and the defective code will be displayed on the screen.
5. It is suitable for sterilization of instruments containing cavity and solid instruments, and it can be non-wrapped sterilization.

STC-5000:

1. The sterilization effect is reliable and rapid. The whole process of non-wrapped sterilization takes 9 minutes, which is suitable for multi-department equipment operation and emergency.
2. Equipment size: 58 CM*46 CM*19CM; sterilization chamber size :38CM*18CM* 7.8cm; Sterilization box size (outside) : 48 CM *19.6 CM *8 CM.
3. It is easy to operate, the system operation is displayed on the screen; Sterilization procedures can be safely interrupted at any time.
4. With self-detection system, if a problem occurs in the process of operation, the system will automatically stop and the defective code will be displayed on the screen.
5. It is suitable for sterilization of instruments containing cavity and solid instruments, and it can be non-wrapped sterilization

STC-6000:

1. The sterilization effect is reliable and rapid. The whole process of non-wrapped sterilization takes 9 minutes, which is suitable for multi-department equipment operation and emergency.
2. Equipment size: 58 CM*46 CM*19CM; sterilization chamber size :48 CM*18CM* 7.8cm; Sterilization box size (outside) : 57CM*21CM*8CM.
3. It is easy to operate, the system operation is displayed on the screen; Sterilization procedures can be safely interrupted at any time.
4. With self-detection system, if a problem occurs in the process of operation, the system will automatically stop and the defective code will be displayed on the screen.
5. It is suitable for sterilization of instruments containing cavity and solid instruments, and it can be non-wrapped sterilization.

Specifications

Model STC-2000 STC-5000 STC-6000
Maximum Operating Pressure 242 kPa
Operating Pressure Range 42 kPa ~ 212kPa
Maximum Operating Temperature 138° C
Operating Temperature Range 115 ° C – 135 ° C
Sterilization Volume About 1.8 Liters About 5.2 Liters About 6.0 Liters
Tank Volume 3.4 Liters 3.4 Liters 3.4 Liters
Water Ultra-pure water, deionized water, laboratory water. Ultra-pure water, deionized water, laboratory water, distilled water,purified water. Ultra-pure water, deionized water, laboratory water, distilled water,purified water.
Power Supply Voltage AC 220 V±22 V
Power Frequency 50 Hz ± 1 Hz
Input Power ≤1.3 kVA
Atmospheric Pressure Range 70.0 kPa to 106.0 kPa
Ambient Temperature Range + 5 ° C ~ + 40 ° C
Steam Generator Power 1.2 kVA ± 5%
Fuse F8AL250V phi 5 x 20 mm
Safety Valve Setting Pressure 0.25 MPa
Equipment Working Medium Water Vapor
Working Relative Humidity ≤85%
Normal Use Place Work room
Run Mode Run Intermittently (≤6 cycles/hour)

Forced Air Removal Design

Details:

Simple operation                                                   Standard printer, real-time record for sterilization process

Ultra-thin cassette box design makes                                            0.22μm Biofilter

heating and cooling faster

Cassette Sterilizer

Sterilization Chart                                                             Sterilization Cycle Comparison

A. Air removal   B. Warming up                                             Advantages:

C. Pressurizing   D. Sterilizing  E. Venting                           Shorter cycle time, higher efficiency