- Interior Volume: 250L, 350L, 450L
- Cycle Mode: Forced convection, rear micropore. Supply air in front of the plate
- Coolant: R134a
- Defrosting Structure: Automatic
- Humidity Control Mode: Automatic
Climate Chamber, ICB-CC-50 Series
Description
1. Independent humidification, uniform humidity.
2. Centrifugal turbo forced air supply, the temperature is more uniform.
3. Intelligent frost.
Specifications
Model | ICB-CC250-3 | ICB-CC350-3 | ICB-CC450-3 | |
Cycle Mode | Forced convection, rear micropore. Supply air in front of the plate | |||
Function | Temp. Range | Without illumination: 0~65℃
With illumination: 10~65℃ |
||
Temp. Resolution Ratio | 0.1℃ | |||
Temp. Motion | ±1℃ | |||
Temp. Uniformity | ±1.0℃ | |||
Illumination(LX) | Full spectrum0-30000LX many degrees for adjusting | |||
Humidity Range | 40%~95%RH | |||
Humidity Motion | ±5% RH | |||
Structure | Inner Chamber | SUS304satinless steel sheet | ||
Outside Material | Cold rolling steel electrostatic spraying exterior | |||
Thermal Insulation Material | Polyurethane | |||
Light Barrier | Standard four layer full spectrum LED lamp board | |||
Heater | Stainless steel heating tube | |||
Power Rating | 2.0kw | 2.2kw | 2.5kw | |
Compressor | Air cooled hermetic compressor | |||
Coolant | R134a | |||
Defrosting Structure | Automatic | |||
Humidity Control Mode | Automatic | |||
Leading Wire Hole | The outer diameter of standard inflation port interface is 10mm | |||
Controller | Temp. Control mode | 30 sections program | ||
Temp. Setting mode | Touch screen settings | |||
Temp. Display mode | 7.0 inch true color touch screen display | |||
Operation Function | Fixed temperature operation, timing function, auto stop. | |||
Program Pattern | Standard configuration | |||
Sensor | PT100 Temp. Sensor, Imported chip humidity sensor | |||
Additional Function | Reservation switch, historical temperature and humidity data curve query, U disk data storage and export, deviation correction,menu locked, power failure back-up, power failure memory,intelligent defrosting | |||
Safety device | Over temperature will automatically cut off the heating, long-term under temperature cut off the refrigeration system, protect the sample; loop self diagnosis | |||
Specification | Inner Chamber Size(W×L×H)(mm) | 600×500×840 | 620×570×950 | 630×670×1100 |
Exterior Size (W×L×H)(mm) | 794×726×1600 | 814×796×1710 | 824×896×1860 | |
Packing Size (W×L×H)(mm) | 894×826×1800 | 914×896×1810 | 924×996×2060 | |
Volume | 250L | 350L | 450L | |
Load Per Rack | 15kg | |||
Shelf Number | 6 | 6 | 7 | |
Shelf Space | 120mm | |||
Supply (50/60Hz) Current Rating | AC220V/4.5A | AC220V/5.0A | AC220V/5.5A | |
NW/GW (kg) | 76/117 | 78/119 | 81/122 | |
Accessory | Shelf | 4 | ||
Shelf Plate | 8 | |||
Optional accessories | Light barrier, USB (ICB-CC350-3 is standard), printer, wireless SMS alarm, CO2 concentration control |