- Sterilization Volume: 1.8 – 6 L
- The whole sterilization process is about 6-9 minutes
- Temperature range: 135 ° C- 138° C
- Maximum Operating Pressure: 242 kPa
Cassette Dental Autoclave, STC Series
Description
DESCRIPTION
DESCRIPTION
At 6-9 minutes cycle, STC Series Cassette Dental Autoclave offer easily one of the faster sterilizers on the market, the sterilization effect is reliable and rapid. It is suitable for dental equipment operation and emergency due to its compact size and short sterilization cycle. This cassette dental autoclave is designed for sterilization of all reusable instruments, including complex constructions, whether packaged or not.
1. It is easy to operate, the system operation is displayed on the screen; Sterilization procedures can be safely interrupted at any time.
2. With self-detection system, if a problem occurs in the process of operation, the system will automatically stop and the defective code will be displayed on the screen.
3. It is suitable for sterilization of instruments containing cavity and solid instruments, and it can be non-wrapped sterilization
4. Small dimensions, light weight, wide ambient working conditions, easy to operate. the cassette is also a good medical instruments container for temporary deposit and carry.
5. Compared with the autoclave with a longer sterilization cycle, this quick autoclave prolongs the lifespan of the medical instruments relatively.
- Easy to operate
- The system operation is displayed on the screen
- Sterilization procedures can be safely interrupted at any time
- Standard printer
- Real-time record for sterilization process
- Ultra-thin cassette box design makes heating and cooling faster
- 0.22μm Biofilter
Shorter cycle time, higher efficiency
- A: Displace
- B: Heat up
- C: Sterilization
- D: Exhaust
- E: Dry
SPECIFICATIONS
SPECIFICATIONS
Model | STC-2000 | STC-5000 | STC-6000 |
Maximum Operating Pressure | 242 kPa | ||
Operating Pressure Range | 42 kPa ~ 212kPa | ||
Maximum Operating Temperature | 138° C | ||
Operating Temperature Range | 115 ° C to 135 ° C | ||
Sterilization Volume | About 1.8 Liters | About 5.2 Liters | About 6.0 Liters |
Tank Volume | 3.4 Liters | ||
Water | Ultra-pure water, deionized water, laboratory water. | Ultra-pure water, deionized water, laboratory water, distilled water, purified water. | |
Power Supply Voltage | AC 220 V±22 V | ||
Power Frequency | 50 Hz ± 1 Hz | ||
Input Power | ≤1.3 kVA | ||
Atmospheric Pressure Range | 70.0 kPa to 106.0 kPa | ||
Ambient Temperature Range | + 5 ° C ~ + 40 ° C | ||
Steam Generator Power | 1.2 kVA ± 5% | ||
Fuse | F8AL250V phi 5 x 20 mm | ||
Safety Valve Setting Pressure | 0.25 MPa | ||
Equipment Working Medium | Water Vapor | ||
Working Relative Humidity | ≤85% | ||
Normal Use Place | Work room | ||
Run Mode | Run Intermittently (≤6 cycles/hour) |