- Max. Temp.: 1200℃
- Continuous working temp: ≤1100℃
- Thermal couple: K type
- Heating element: Resistance wire with Mo
Muffle Furnace, 1200℃ High Temp, Box Type, FNC-BX1200 Series
Description
FNC-BX1200-1 FNC-BX1200-2II/FNC-BX1200-3/FNC-BX1200-6/FNC-BX1200-9
1. 1200°C maximum operating temperature;
2. High purity fibrous alumina insulation for maximum energy saving;
3. Double layer steel structure with air cooling fan to keep furnace’s exteriors safe to touch;
4. Safety interlock with automatic power off the furnace when door is opened;
5. PID automatic control via current limiting phase angle fired the resistor, e.g. SC R (Silicon Controlled Rectifier);
6. Power control with 30 segments programmable.
Accessories (specify these at time of order)
1. Standard Accessories
Thermal gloves | Crucible Tongs | Thermocouple | Furnace Door Block | User Manual
2. Optional
Different chamber size for your choose;
LCD touch screen control for choose
Program software to connect computer for choose.
Content may be subject to modifications or corrections
Specifications
Model | FNC-BX1200-1 | FNC-BX1200-2II | FNC-BX1200-3 | FNC-BX1200-6 | FNC-BX1200-9 |
Max. Temp (℃) | 1200℃ | 1200℃ | 1200℃ | 1200℃ | 1200℃ |
Continuous working temp. | ≤1100℃ | ≤1100℃ | ≤1100℃ | ≤1100℃ | ≤1100℃ |
Chamber size (mm) W*D*H | 100×100×100 | 150×200×150 | 200×300×120 | 200×300×200 | 300×400×300 |
Or customize as your requirement | Or customize as your requirement | Or customize as your requirement | Or customize as your requirement | Or customize as your requirement | |
Heating element | Resistance wire with Mo | Resistance wire with Mo | Resistance wire with Mo | Resistance wire with Mo | Resistance wire with Mo |
Thermal couple | K type | K type | K type | K type | K type |
Chamber material | High purity alumina polycrystalline fiber | High purity alumina polycrystalline fiber | High purity alumina poly crystalline fiber | High purity alumina polycrystalline fiber | High purity alumina polycrystalline fiber |
Heating rate | 0~30℃/min, suggest to be 15℃/min; | 0~30℃/min, suggest to be 15℃/min; | 0~30℃/min, suggest to be 15℃/min; | 0~30℃/min, suggest to be 15℃/min; | 0~30℃/min, suggest to be 15℃/min; |
Thermal control accuracy | ±1℃ | ±1℃ | ±1℃ | ±1℃ | ±1℃ |
Temperature uniformity | ±5℃ | ±5℃ | ±5℃ | ±5℃ | ±5℃ |
Power supply | AC 100V-415V, 50Hz/60Hz | AC 100V-415V, 50Hz/60Hz | AC 100V-415V, 50Hz/60Hz | AC 100V-415V, 50Hz/60Hz | AC 100V-415V, 50Hz/60Hz |
Max. Power W*D*H | 1kW for 100×100×100(mm) | 2kW for 150×200×150(mm) | 3kW for 200×300×120(mm) | 6kW for 200×300×200 (mm) |
9kW for 300×400×300(mm) |
Please note:
- Heat up rate is measured by using an empty chamber.
- Holding power is measured at continuous operating temperature.
Get Social