- Measure CO, HC, CO2, O2concentration
- Large screen LCD display, Englishmenu
- Adoptsinfrared detector and O2 sensor
Automobile Exhaust Analyzer, AEA-H400
Description
Description
It is used to measure CO, HC, CO2, O2 concentration and λ value, COcor, speed, oil temperature, flow, pressure and can measure vehicles fueled by gasoline, LPG, CNG and alcohol;
Features
- Large screen LCD display, Englishmenu.
- Adoptsinfrared detector and O2 sensor imported from Germany, not afraid of vibration, good stability and high precision.
- Single idle speed, double idle speed and general measurement function.
- Automatic zero adjustment, automatic cleaning, automatic temperature compensation and pressure compensation;
- Has HC residual measurement, flow monitoring and gas path leakage inspection.
- There is self diagnosis function in the machine, and there will be a prompt in case of fault, and the measurement can be continued until the fault is eliminated;
- Optional speed and oil temperature measurement, optional built-in printer or Bluetooth, RS232, analog interface.
- License plate number input and 500 sets of data storage, reference function, clock display.
Specifications
Model | AEA-H400 |
Measuring Range | HC: 0~10000×10-6(ppm) vol |
CO: 0~10 ×10-2(%)vol | |
CO2:0~20×10-2(%)vol | |
O2: 0~25×10-2(%)vol | |
λ:0.50~3.00 | |
COcor:0~10×10-2(%)vol | |
Speed:0-9999rpm | |
Oil temp.:0-150℃ | |
Indicating Error | HC±12 ×10-6 (ppm) vol (absolute error) or ±5% (relative error) |
CO±0.06×10-2(%)vol (absolute error)or ±5%(relative error) | |
CO2 ±0.5×10-2(%)vol (absolute error)or ±5%(relative error) | |
O2 ±0.1 ×10-2(%)vol (absolute error)or ±5%(relative error) | |
Stability | Automatic zero calibration, torque drift ≤ ± 3% |
Repeatability | Repeatability error≤±2% |
Resolution | HC: 1×10-6(ppm)vol |
CO: 0.01×10-2(%)vol | |
CO2: 0.1×10-2(%)vol | |
O2: 0.01×10-2(%)vol | |
λ:0.01 | |
Speed:10rpm | |
Oil temp.:0.1℃ | |
Response Time | 95% response is not more than 10 seconds |
Preheating Time | 8 minutes (preheating for 3 minutes for emergency detection) |
Output Mode | Can be displayed on the screen, can print the maximum value, average value, minimum value of gas concentration and the license plate number, test time, date, speed, oil temperature and λ, COcor value, and can be connected to the computer with an interface. |
Ambient Condition | Temperature: -5~50℃, relative humidity≤90% |
Electricity | AC100-240V, 50/60Hz or DC12V (Optional power inverter) |
Power Consumption | 40VA |
External Dimension (L*W*H) | 420*310*170mm |
Net Weight | 9kg |