- 7 inches TFT LCD
- 1 or 2 points Calibration
- For the laboratory to determine the Do, BOD, OUR and SOUR of the sample.
- Memory: 1000 data sets
- Accuracy: ±0.2mg/L, ±2.0%
Dissolved oxygen Meter, benchtop, BEP-M180/BEP-M181
Description
Measurement Parameters
BEP-M180: Dissolved oxygen, BOD, oxygen uptake rate, specific oxygen uptake rate
BEP-M181: Dissolved oxygen
BEP-M180: Dissolved oxygen, BOD, oxygen uptake rate, specific oxygen uptake rate
BEP-M181: Dissolved oxygen
Features
- 1 or 2 points calibration using the air-saturated water or zero oxygen solution.
- Salinity and barometric pressure compensations eliminate the measurement error.
- selectable testing time, beginning/ending DO are used for the OUR/SOUR calculations
- Auto-Read function senses and locks the measurement endpoint
- Timed Interval Readings send the measurement data to a PC or printer
- Limit Alarm automatically alerts when reading exceeds the specified range
- Calibration due alarm prompts the user to calibrate the meter regularly
- Password protection prevents the unauthorized calibration and settings
- Expanded memory stores or recalls up to 1000 data sets
- Reset function automatically resumes all settings back to the factory defaults
Ordering Information
BEP-M180,181: Meter, DO100 dissolved oxygen electrode, electrolyte solution, membrane cap, electrode holder and power adapter
BEP-M180,181: Meter, DO100 dissolved oxygen electrode, electrolyte solution, membrane cap, electrode holder and power adapter
Specifications
Model | BEP-M180 | BEP-M181 | ||
DO | Range | 0.00~20.00mg/L, 0.0~200.0% saturation | • | • |
Resolution | 0.01mg/L,0.1% | • | • | |
Accuracy | ±0.2mg/L, ±2.0% | • | • | |
Other Specifications | Calibration Points | 1 or 2 points | • | • |
Temperature Compensation | 0~50°C/32~122°F, automatic | • | • | |
Barometric Pressure Correction | 60.0~113.3kPa/450~850mmHg, manual | • | • | |
Salinity Correction | 0.0~50.0g/L, manual | • | • | |
BOD/OU/SOUR Measurement | For model BEP-M180 only | • | – | |
Stability Criteria | Standard or high-accuracy | • | • | |
Calibration Due Alarm | 1 to 31 days or off | • | • | |
Interval Readings | 10, 30, 60 seconds, 10, 30 minutes or off | • | • | |
Memory | 1000 data sets | • | • | |
Communication Interface | USB | • | • | |
Connector | 6 pin mini-DIN | • | • | |
Display | 7 inches TFT LCD | • | • | |
Power Requirements | DC12V power adapter | • | • | |
Dimensions | 240(L)× 220 (W)× 80(H)mm | • | • | |
Weight | 1.7kg | • | • |