- Detector: FID/TCD optional
- 20 groups of sample test mode memory function
- Can match automatic sampler of various specifications
Gas Chromatograph, GC-I112N
Description
- Standard PC side reverse control software, built-in chromatographic workstation, achieve PC side reverse control and host touch screen synchronous bidirectional control. (GC-I112N only)
- Host with 7-inch color touch screen, carrier/hydrogen/air channel flow (pressure) digital display.
- Gas shortage alarm protection function; Heating control protection function (when opening the door of the column box, the motor of the column box fan and the heating system will shut down automatically).
- Split flow/split ratio can be automatically controlled to save carrier gas.
- Configure automatic sampler installation and positioning interface to match automatic sampler of various specifications.
- The multi-core, 32-bit embedded hardware system ensures the reliable operation of the instrument.
- One-button start function, with 20 groups of sample test mode memory function.
- Using logarithmic amplifier, detection signal no cut-off value, good peak shape, extensible synchronous external trigger function, can be started by external signals (automatic sampler, thermal analyzer, etc.) at the same time the host and workstation.
- It has perfect system self-check function and fault automatic identification function.
- With 8 external event extension function interface, can be selected with various function control valves, and according to their own set time sequence work.
- RS232 communication port and LAM network port, and the configuration of data acquisition card.
Specifications
Oven
- Content product: 22L
- Temperature control range: 5℃ ~ 400℃ at room temperature
- Temperature control accuracy: ±0.1℃
- Heating rate: 0.1 ~ 60℃ / min
- Program temperature rise order: 9
- Program heating repeatability: ≤ 2%
- Cooling way: open the door after
- Cooling speed: ≤10 mins (250℃ ~ 50℃)
Sampler Injector
- Temperature control range: 7℃ ~ 420℃ at room temperature
- Temperature control method: independent temperature control
- Carrier gas flow control mode: constant pressure
- Number of simultaneous installations: 3 at most
- Type of injection unit: filling column, shunt
- Split ratio: split ratio display
- Cylinder pressure range: 0 ~ 400kPa
- Cylinder pressure control accuracy: 0.1kPa
- Flow setting range: H2 0 ~ 200ml / min N2 0 ~ 150ml / min
Detector
- FID, TCD optional
- Temperature control: Max. 420℃
- Number of simultaneous installations: 2 at most
- Ignition function: automatic
- Hydrogen flame ionization detector (FID)
Detection limit: ≤ 3×10-12 g/s (n-hexadecane)
Baseline noise: ≤ 5× 10-14A
Baseline drift: ≤ 6× 10-13A
Dynamic range: 107
RSD: 3% or less - Thermal conductivity detector (TCD)
Sensitivity: 5000mV•mL/mg (n-cetane)
Baseline noise: ≤ 0.05 mV
Baseline drift: ≤ 0.15mV / 30min
Dynamic range: 105 - Supply voltage: AC220V±22V, 50Hz±0.5Hz
- Power: 3000W
Optional
- N2000 chromatography workstation
- Packed column
- Capillary column
Get Social