Home>Products>Elemental Analysis
    1. Temperature range: Room temperature +5℃~ 300℃
    2. Measuring range: 0.1 ~ 100%
    3. Temperature accuracy: ±1℃
    4. Reproducibility: Relative error 1%
    5. Sample weight: 0.5 ~ 15g
    1. Measuring range: 0.1mg~240mg N
    2. Recovery: ≧99.5%
    3. Sample capacity: solid≦6g/sample, liquid≦16mL/sample
    4. Distillation speed: 3-6min/sample
    1. High accuracy dozing and working: adopt 4 KNF pumps work for dozing, measurement liquid volume.
    2. Easy Maintenance: Pre-install functions of cleaning, include receiving cup cleaning, alkali pipeline cleaning, boric acid pipeline cleaning, acid washing, steam bottle evacuation.
    3. support customer make the routine maintenance easily.
    4. High titration accuracy, up to 2.0μL/step.
    5. Integrated printer on the instruments.
    • Measuring range: 0.1mg ~ 240mg N
    • Analysis time: 5 ~ 10min/sample
    • Reproducibility: Average value relative error ≤±0.5%
    • Recovery: ≧99.5%
    1. Analytical range:0.1—200 mg N
    2. Accuracy(RSD):≤0.5%(30mgN,0.1mol/L H+)
    3. Titrant concentration input mode:Manual input
    4. Sample analysis time:3-4min/( cooling water temp 18℃)
    5. Blank deduction of sample:Automatic deduction
    6. User-made recipe:99 groups
    1. Analytical range: 0.1—200 mg N
    2. Accuracy  (RSD):≤0.5% (30mgN,0.1mol/L H+)
    3. Recovery rate: ≥99.5%
    4. Titration accuracy: 0.75μL/step
    5. Titrant concentration range: 0.01—5 mol/L
    • Measuring range: 0.1mg ~240mg N
    • Analysis time: 3~8min/sample
    • Reproducibility  Average value relative error ±0.5%
    • Recovery: ≧99.5%
    1. graphite S and aluminum alloy L to choose.
    2. over-temperature protection
    3. 0-40 sections of program
    4. Number of sample holes:8, 10, 15, 20 holes
    5. Designed temperature:600℃ / 400℃
    1. Welded by stainless steel plate
    2. Collection port:8, 10, 15, 20
    3. Extraction opening: 1, 2
    1. Measuring range:0.1%-100%
    2. Temperature control range:RT+5℃-300℃
    3. Temperature control accuracy: ±1℃
    4. Sample quantity:6 /per time
    5. Solvent cup volume:100mL
    1. KJD-SCB-A is an acid and alkali neutralization equipment with its own negative pressure pump,and it has large flow rate with long-life service,and most importantly it is easy to use.
    2. The secondary filter procedure of alkali liquor and distilled water ensures the exhaust gas reaching discharge standard.
    3. Due to the large contact surface between gas and liquid, the neutralization efficiency is high,and the exhaust gas is pollution-free.
    1. Designed temperature:RT-200℃
    2. Temperature control table:Liquid crystal display/±1℃
    3. Heating module material:Aluminium alloy
    4. Timing range:0—99 hours
    1. Temperature range: Room temperature+5℃~ 280℃
    2. Measuring range: 0 ~ 100%
    3. Temperature accuracy: ±1℃
    4. Sample weight: 0.5 ~ 15g(generally 2 ~ 5g,depending on sample)
    1. Measurement range: 0.1% ~ 100%
    2. Sample weight: 0.5g ~ 3g
    3. Hidden solution barrel pull structure
    4. The crucible recoil function designed
    5. With dosing overflow protection function
    6. Adjust the crucible heating power in time
    7. Having a built-in pre-heating function
    8. Integrated infrared heating technology
    1. The scrubber for Digesters
    2. Ternary filtration system
    3. Suction pressure is adjustable
    1. Temperature range: RT. +5 - 450℃
    2. Temperature accuracy: ±1℃
    3. Digestion tube capacity: 300mL